Abstract:

Cooling towers are evaporative heat transfer devices in which atmospheric air cools warm water, with direct contact between the water and the air, by evaporating part of the water, mostly used inair conditioning and industrial processes. Cooling efficiency of a natural draft, dry cooling tower (NDDCT) is significantly affected under cross-wind condition. This paper investigates a solution that may improve cooling performance of cooling towers, with particular interest in peripheralwind breakers methods around towers. The study explores a realistic scenario with four cooling towers in-square arrangement. A power plant cooling towers performance has been modelednumerically for different distances of peripheral wind breakers. The results are compared and it is concluded that the peripheral wind breaker at 25 m has the best efficiency improvement

Authors

Farshad Kimiaghalam

Department of Mechanical Engineering, K.N.Toosi University of Technology, Tehran, Iran

Jahanfar Khaleghinia

Department of Mechanical Engineering, Nour Branch , Islamic Azad University, Nour, Iran

Mostafa Mafi

Department of Mechanical Engineering, Imam Khomeini International University, Qazvin, Iran

مراجع و منابع این Paper:

لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :
  • Cooling Tower Institute, CTI Code Tower, Standard specifications, acceptance test ...
  • Willa JL. Evolution of the cooling tower. CTI J 1992;1 ...
  • Mirsky GR, Bauthier J. Evolution of cooling tower fill. CTI ...
  • Wallis JS, Aull RJ. Improving cooling tower performance. Hydrocarbon Eng ...
  • Aull RJ, Krell T. Design features of cross-fluted film fil ...
  • Khan JR, Qureshi BA, Zubair SM. A comprehensive design and ...
  • Merkel F. Verdun stungskihlung _ VDI-Zeitchrit 1925; 70(1):123-8. ...
  • Jaber H, Webb RL. Design of cooling towers by the ...
  • Poppe M, Rigener H. Berechnung von Rii ckkiihlwerken _ VD ...
  • Kloppers JCKroger DG. Cooling tower performance evaluation: Merkel, Poppe, and ...
  • Goshayshi HR, Missenden JF The investigation of cooling tower packing ...
  • Milosavljevic N, Heikkila P. A comprehensive approach to cooling tower ...
  • Lemouari M, Boumaza M, Mujtaba IM. Thermal performances investigation of ...
  • Cortinovis GF, Paiva JL, Song TW, Pinto JM. A systemic ...
  • Yao Y, Lian ZW, Hou ZJ, Zhou XJ. Optimal operation ...
  • Soylemez MS. On the optimum performance of forced draft counter ...
  • Muangnoi T, Asvapoositul W, Wongwises S. An exergy analysis On ...
  • Ataei A, Panjeshahi MH, Gharaie M. Performance evaluation of counter-flow ...
  • The _ National Chemical Engineering Congress (IChEC 2012) Sharif University ...
  • Q. Wei et al., A study of the unfavorable effects ...
  • M.D. Su, G.F. Tang, S. Fu, Numerical simulation of fluid ...
  • S. Fu, Z. Zhai, Numerical investigation of the adverse effect ...
  • نمایش کامل مراجع