PSEUDO BOND GRAPH STRUCTURAL MODELING FOR ZONE CONTROL OF HEATING SYSTEMS IN DWELLINGS FOR ENERGY CONSERVATION
Publish place: 05th International Power System Conference
Publish Year: 1369
نوع سند: مقاله کنفرانسی
زبان: English
View: 1,652
This Paper With 7 Page And PDF Format Ready To Download
- Certificate
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
PSC05_025
تاریخ نمایه سازی: 25 مرداد 1386
Abstract:
A bond graph model for energy flow in the ideal dwellings is presented . This model has been used to numerically simulate the thermal behavior of an ideal tract home subject to both single thermostat and multiple thermostat zone control . Several simulations have been run,each with a different number of controlled zones t o evaluate possible energy savings of retrofit zone control . In al 1 cases , multiple thermostat control resulted in an energy savings. The largest savings , 32% occured in the two thermostat case.
Authors
Said Azarbaijani
P.h.D.۱P.E. Tehran Regional Electric Company Tehran , Iran
مراجع و منابع این Paper:
لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :